Net Power |
185 kW |
Operating Weight |
21950 kg |
Brakes |
Single Disc Wet (enclosed) 4 WHL |
Ground to Top of Beacon |
3994 mm |
Ground to Top of Exhaust Stack |
3392 mm |
Ground to Top of Hood |
2614 mm |
Length of Coal Blade on Ground |
7784 mm |
Length to Front Tire |
6356 mm |
Bore |
105 mm |
Displacement |
7.01 l |
Emissions |
Brazil MAR-1 and China Nonroad Stage III, equivalent to U.S. EPA Tier 3/EU Stage IIIA |
Engine Model |
Cat C7.1 ACERT |
Peak Power Speed |
2200 r/min |
Peak Power Speed – Gross – SAE J1995 |
213 kW |
Peak Power Speed – Net – SAE J1349 |
186 kW |
Peak Torque – 1,400 rpm |
1016 N·m |
Rated Speed |
2200 r/min |
Stroke |
135 mm |
Torque Rise |
26% |
Bore |
105 mm |
Displacement |
7.01 l |
Emissions |
U.S. EPA Tier 4 Final/EU Stage IV |
Engine Model |
Cat C7.1 ACERT |
Peak Power Speed |
1700 r/min |
Peak Power Speed – Gross – SAE J1995 |
212 kW |
Peak Power Speed – Net – SAE J1349 |
185 kW |
Peak Torque – 1,400 rpm |
1219 N·m |
Rated Speed |
2200 r/min |
Stroke |
135 mm |
Torque Rise |
52% |
Cylinders, Double Acting – Left and Right Tilt, Bore and Stroke |
101.6 mm × 234 mm (4.0 in × 9.2 in) |
Cylinders, Double Acting – Lift, Bore and Stroke |
120 mm × 915 mm (4.7 in × 36.0 in) |
Lift/Tilt System |
Variable displacement piston |
Lift/Tilt System – Circuit |
Pilot operated LS valve with EH |
Maximum Flow at 2,200 rpm |
89 l/min |
Pilot Relief Valve Setting |
21000 kPa |
Pilot System |
Open center, fixed displacement gear |
Relief Valve Setting – Lift/Tilt |
22000 kPa |
Maximum Flow at 2,200 rpm |
147 l/min |
Relief Valve Setting – Steering |
27600 kPa |
Steering Cycle Times – High Idle |
3 s |
Steering Cycle Times – Low Idle |
8.2 s |
Total Steering Angle |
72° |
Operating Weight |
21671 kg |
Operating Weight |
21950 kg |
AC Oil |
126 ml |
AC Refrigerant |
19 hg |
Cooling Systems – Brazil MAR-1 and China Nonroad Stage III, equivalent to Tier 3/Stage IIIA |
73 l |
Cooling Systems – Tier 4 Final/Stage IV |
81 l |
Diesel Exhaust Fluid Tank |
16 l |
Hydraulic System – Implement |
N/A |
Hydraulic System – Implement/Steering |
129 l |
Hydraulic System – Steering |
N/A |
Oil Renewal System (ORS) |
N/A |
Machine Sound Level (ISO 6395) |
112 dB(A) |
Note (1) |
The operator sound pressure level was measured according to the test procedures and conditions specified in ISO 6396:2008. The measurement was conducted at the maximum engine cooling fan speed. |
Note (2) |
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment. |
Note (3) |
The machine sound power level was measured according to the test procedures and conditions specified in ISO 6395:2008. The measurement was conducted at the maximum engine cooling fan speed. |
Operator Sound Level (ISO 6396) |
71 dB(A) |
Machine Sound Level (ISO 6395) |
110 dB(A) |
Note (1) |
The operator sound pressure level was measured according to the test procedures and conditions specified in ISO 6396:2008. The measurement was conducted at the maximum engine cooling fan speed. |
Note (2) |
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment. |
Note (3) |
The machine sound power level was measured according to the test procedures and conditions specified in ISO 6395:2008. The measurement was conducted at the maximum engine cooling fan speed. |
Operator Sound Level (ISO 6396) |
70 dB(A) |
Machine Sound Level (ISO 6395) |
111 dB(A) |
Note (1) |
The operator sound pressure level was measured according to the test procedures and conditions specified in ISO 6396:2008. The measurement was conducted at the maximum engine cooling fan speed. |
Note (2) |
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment. |
Note (3) |
The machine sound power level was measured according to the test procedures and conditions specified in ISO 6395:2008. The measurement was conducted at the maximum engine cooling fan speed. |
Operator Sound Level (ISO 6396) |
71 dB(A) |
Machine Sound Level (ISO 6395) |
109 dB(A) |
Note (1) |
The operator sound pressure level was measured according to the test procedures and conditions specified in ISO 6396:2008. The measurement was conducted at the maximum engine cooling fan speed. |
Note (2) |
Hearing protection may be needed when the machine is operated with a cab that is not properly maintained or when the doors or windows are open for extended periods or in a noisy environment. |
Note (3) |
The machine sound power level was measured according to the test procedures and conditions specified in ISO 6395:2008. The measurement was conducted at the maximum engine cooling fan speed. |
Operator Sound Level (ISO 6396) |
70 dB(A) |
Forward – 1 |
5.7 km/h |
Forward – 2 |
10.1 km/h |
Forward – 3 |
17.6 km/h |
Forward – 4 |
30.5 km/h |
Reverse – 1 |
6.5 km/h |
Reverse – 2 |
11.5 km/h |
Reverse – 3 |
20.1 km/h |
Reverse – 4 |
34.6 km/h |
Engine Model |
Cat® C7.1 ACERT™ |
Transmission Type |
Cat Planetary Power Shift |
Front |
Planetary – Fixed |
Oscillation Angle |
±10° |
Rear |
Planetary – Oscillating |
Differential – Final Drives – Front |
65 l |
Differential – Final Drives – Rear |
65 l |
Engine Crankcase |
20 l |
Fuel Tank |
500 l |
Hydraulic Tank Only |
75 l |
Transmission |
50 l |
Centerline of Front Axle to Hitch |
1675 mm |
Centerline of Rear Axle to Edge of Bumper |
1990 mm |
Ground Clearance |
413 mm |
Ground Clearance – Bumper |
712 mm |
Height – Top of Cab |
3694 mm |
Length – With Blade on Ground – Straight Blade |
7190 mm |
Wheel Base |
3350 mm |
Steering System – Circuit |
Pilot, load sensing |
Steering System – Pump |
Variable displacement piston |